I. Kalibrlashdan oldin tayyorlash
Uskunani tekshirish: kalibrlash dastgohi, bosim o'lchagich va boshqa asboblar yaxshi holatda ekanligini tasdiqlang.
Vizual tekshirish: Yorliq va valf korpusida zang borligini tekshiring va barcha qismlar to'liq ekanligiga ishonch hosil qiling.
II. Bosim sinovini o'rnating
O'rnatish: xavfsizlik valfini kalibrlash dastgohiga mahkamlang.
Bosimning oshishi: bosimni o'rnatilgan bosimning 90% ga sekin oshiring, so'ngra bosimni 0,01 MPa/s dan kam yoki unga teng tezlikda oshiring.
Yozish: Muhitning uzluksiz zaryadsizlanishini eshitganingizda bosim qiymatini yozib oling. 3 marta takrorlang va o'rtachani oling.
III. Qayta o'rnatish bosimi sinovi
Bosimning pasayishi: o'rnatilgan bosimdan bosimni sekin pasaytiring.
Yozish: xavfsizlik valfi yopilganda bosim qiymatini yozib oling.
IV. Muhrlash sinovi
Bosim: muhrlangan sirtni belgilangan bosimning 90% ostida tekshiring.
Standard: When the set pressure is ≤0.3 MPa, the sealing pressure is 0.03 MPa lower than the set pressure; when >0,3 MPa, muhrlanish bosimi belgilangan bosimning 90% ni tashkil qiladi.
V. Sozlash va qayta-tekshirish
Sozlash: bahor tarangligini yoki qarshi og'irlik holatini sozlash orqali bosim qiymatini to'g'rilang.
Qayta-tekshiruv: sinovdan o'tguncha takrorlang.
VI. Muhr va yozuvlar
Muhrlash: sozlashni oldini olish uchun idishni o'tgandan keyin muhrlab qo'ying.
Yozuvlar: Boshlanish bosimi va qayta o'rnatish bosimi kabi ma'lumotlarni arxivlash.
VII. Kalibrlash davri
Yangi jo'natish: Agar kerak bo'lsa, ishlatishdan oldin kalibrlang.
Davriy: "Bosimli idishlarni davriy tekshirish qoidalari" ga muvofiq bajaring.
VIII. Ehtiyot choralari
Media: Odatda havo yoki azot ishlatiladi.
Xavfsizlik: Shamollatish teshigi xodimlardan uzoqqa qaragan bo'lishi kerak; boshingizni xavfsizlik klapanining tepasidan uzoqroq tuting.
Atrof-muhit: korroziya va tiqilib qolishning oldini olish; shamollatgichni toza tuting.